Picoway super picosecond

Picoway super picosecond

 


one,Introduction

Picosecond laser is a laser whose pulse duration (pulse width) of each laser emission reaches the picosecond level; it uses the most cutting-edge technology to treat pigmentary diseases. Through the principle of fast and powerful energy, the pigment in the skin is more finely crushed, and then discharged from the body through lymph, thereby completely removing tattoos and stains. Therefore, the treatment process is shortened from the original 10 times to 2 to 3 times. It does not harm the dermis, reduces the possibility of side effects, and improves the success rate of the operation.

two,Treatment range

Remove tattoos, eyeliner, lip line

Epidermal and dermal pigments

Acquired nevus of Ohta (pigmented spots on both sides)

freckle

Melasma…

post-inflammatory pigmentation

age spots

Sun spots/simple spots

coffee spots

 

 

three,Advantages and features

1. High-energy & rapid treatment: high-energy treatment of pigmented spots (tattoos, epidermal spots, dermal spots) in a short period of time

2. High-end performance: Picosecond-level high-speed crushing of large pigment cells and tissue into small debris

3. Comfort & Safety: It can effectively and safely treat various pigment diseases and stubborn spots, because picosecond laser treatment can reduce damage to the skin by accurately locating the target tissue to achieve the effect of removing spots.

4. The skin will not be burned during treatment: Because picosecond laser has only half the energy of traditional laser, the thermal damage to skin tissue is also reduced by half.

5. There will be no anti-darkness problem: The picosecond laser energy instantly focuses and penetrates to the surface of the skin, accelerating the decomposition and metabolism of melanin particles, making it less likely to remain on the skin, and greatly reducing postoperative redness, swelling and anti-darkness.

6. Honeycomb type instant lens: It causes the vacuolation effect of the epidermis, which can protect the epidermis from wounds, activate the tissue repair mechanism, and provide more diversified treatments.

 

4. Treatment principle

Conversion relationship of time units:

1 second = 1000 milliseconds (Millisecond)

1 millisecond = 1000 microseconds (Microsecond)

1 microsecond = 1000 nanoseconds (Nanosecond)

1 nanosecond = 1000 picoseconds (Picosecond)

As the name suggests, a picosecond laser is a laser whose pulse duration (pulse width) emitted by each laser reaches the picosecond level.

According to the principle of selective photothermolysis, the shorter the action time of the laser, the less likely it is for the absorbed and accumulated laser energy in the target tissue to spread to the surrounding tissue. The energy is limited to the target to be treated to a certain extent, protecting the surrounding areas. Normal tissue, the more selective the treatment. The picosecond laser pulse width is only one percent of the traditional Q-switched laser. Under this ultra-short pulse width, the light energy has no time to be converted into heat energy, and almost no photothermal effect is produced. After being absorbed by the target, its volume expands rapidly, producing The photomechanical effect is exploded and torn into fragments, which is more selective and can produce stronger curative effect on pigmented skin lesions in a shorter number of treatments. In one sentence, "Picosecond laser crushes pigment particles more thoroughly and causes less damage to surrounding tissues."

If we compare the original pigment particles to rocks, the traditional Q-switched laser can break these rocks into the size of pebbles, and using the picosecond laser can break them into fine sand, so that the absorption efficiency of the pigment fragments is Greatly improved.

 

5. Accessories list

Accessory box Korean torsion spring light guidearm

 

treatment handle

 

Pedal

 

honeycomb head

water funnel
 

handle hanger

 

Eye patches & glasses

 

eye mask

 

power cable

 

Hex screwdriver

  

 

6. Technical parameters

Technical Data Sheet
Laser typeND:YAG
Laser wavelength532nm, 1064nm (755nm optional)
Laser output energySingle pulse 2.00j
power supply220V/110V
highest energy6J/cm
working frequency1-10HZ
pulse width2000ps
Total power3000W
cooling systemAir cooling, water cooling
Spot diameter2-10mm
net amount140KG
Package Size

7. Safety matters

1. Electrical safety

The laser uses a single-phase 220V/5A or 110V/10A power supply, and the maximum output current is not more than 3A.

The power supply connected to the laser must use a well-grounded single-phase three-wire power socket that complies with national standards and has a specification of at least 5A.

There is high voltage in the laser's memory when it is running. After the power is turned off, the high-voltage components may still have residual voltage - opening the case at will may cause a high-voltage electric shock!

2. Transportation safety

The laser is a large device and is not suitable for mobile use by users. The handle shell of the laser machine is equipped with a precision laser optical system. During transportation, the shock-absorbing packaging provided by the original manufacturer must be used, otherwise it may cause malfunction of the laser system and affect the laser output energy!

The drain hole must be plugged tightly before moving and transporting.

3. System safety device

In order to ensure safe use, the laser is designed with the following safety protection devices:

Stop switch: Convenient for emergency shutdown when unexpected situations occur;

Standby/preparation control: Laser output is prohibited in the standby state, which is the safe state of the system.

4. [Statement]: Low temperature areas below 0℃

If the instrument is not used for a long time or needs to be used in a different location, the water inside (handle and main unit) must be drained.

Try not to leave the instrument in an environment below 0℃ for more than 3 hours. Research has found that water below 0℃ will 'swell' when it moves. Specifically, liquid water below 0℃ will expand when it moves. Rapid freezing will occur during the process. After liquid water turns into solid ice, its volume increases rapidly, causing certain damage to components such as water pipes, cooling fan internal waterways, and laser waterways.

After the customer receives the instrument, it needs to rest for 24 hours at an indoor temperature of 23-26°C before it can be used. If the operation is not performed as required and the instrument is damaged due to the customer's own reasons, our company will only provide paid maintenance services. Due to the influence of temperature, we hope customers can pay attention to it. And comply with requirements and perform routine maintenance.

8. Operation instructions

  • Instrument installation:

    1.1 Light guide arm installation:Take out the light guide arm and put it vertically into the light guide arm connection port of the host, then rotate the nut to fix it;

1.2 Installation of handle hanger:Fix the handle hanger on the light guide arm with screws;


①Pack jack


②Screw fixation

Picoway Superpicosecond: -1

③Complete

1.3 Treatment handle installation:Align the jack with the arrow and insert it into the fastener.

   

1.4 Add water:Insert the drain pipe into the overflow hole on the left side of the bottom of the main unit, insert the funnel into the water filling hole, add distilled water through the funnel until water flows out of the overflow hole, and it is full;

Release water:Insert the drain pipe into the water drain hole on the right side of the bottom of the host, insert the funnel into the water filling hole, and the water will be discharged directly through the drain pipe;

Note: When adding water, a container should be placed at the corresponding position of the overflow port to collect water.

Do not turn on the machine without water at any time

Coolant is purified water or distilled water

When the temperature is below 0°, replace the water with antifreeze

Change the water once a week and drain the water when it needs to be transported

   

1.5 Foot switch and power connection:The foot switch is used to control the laser output. When the foot switch is pressed, the shutter motor's baffle opens and the laser is output from the end of the articulated arm.

 

2. Screen introduction

2.1 Power on:Turn on the power, turn right to pop up the power buttonYou can start the machine;

button key

Boot interface

2.2 Screen introduction:

In standby mode, repeatedly adjust the energy size to 0.1-6J/cm²;

Record the current number of operations;

 

Adjust the red light indicator;

 

 

Energy display;

 

Frequency display;

 

Picoway Superpicosecond: -1Spot size display;

 

(Remark:

The treatment handle can be rotated to adjust the spot size by pushing it upward slightly.2-10)

Application wavelength, optional 1064nm&755nm&532nm

9. Parameter settings

Parameter setting reference table:(The actual operation situation will be adjusted based on the patient’s reflection in the treatment)
light spotEnergyJ/cm²Wavelength nmRemark
Whitening and removing yellowing70.9-1.21064/755Operate until the skin becomes reddish
Epidermal spots4-51.0-1.21064/755The operation is performed until the spots turn white and then slightly bleed.
Dermal spots40.9-1.21064Operate until reddish or rash appears
chloasma60.7-1.01064Operate until it turns white or reddish
spot mole41.0-1.31064Operate until bleeding or whitening occurs
Eyebrow tattoo, lip liner tattoo, eyeliner tattoo61.3-1.51064New tattoo, black and blue, operate until the tattoo turns white
60.9-1.01064Old style tattoo, black and blue, manipulated until the tattoo turns white
50.9-1.0532Wash the color and operate until the tattoo turns white
blackheads51.1-1.31064Knock off the little black head

 

10. Effect comparison chart

11. Operation precautions and taboos

1,Precautions

① It is normal to feel slight tingling during treatment;

②Cannot be used by pregnant women;

③ Cannot be used for bleeding, thrombosis, arteriosclerosis, acute inflammation, joint and soft tissue suppuration;

④ It is forbidden to store it near direct sunlight or heating appliances, especially in summer, choose a good place to place it;

⑤ It is easy to get wet and stay away from places with water or moisture (saunas, bathhouses, etc.), which may cause damage;

⑥ It is forbidden to be impacted by external force to avoid damage. Especially when using the handle, be careful not to drop it to the ground;

⑦ It is forbidden to use chemicals to wipe the instrument (alcohol, benzene, Xina water, etc.), as it will cause damage;

⑧Do not use the instrument continuously for a long time, as it may cause damage;

⑨Keep out of reach of children;

10This instrument should be kept away from sensitive parts such as eyes, Adam's apple, and sexual organs;

11. Do not disassemble and open the inside of the instrument at will.

2. It is prohibited to use this product for physical therapy in the following situations:

1. Patients with edema or edema, and patients with high blood pressure;

2. Persons with severe twitching or restlessness all over the body;

3. Heart disease patients (those with pacemakers, etc.);

4. Those with skin allergies, thinness or loss of elasticity, skin damage or ulcers;

5. Those with severe blood loss, bleeding disorders, bleeding tendencies, or coagulation difficulties;

6 People who do not know how to operate the instrument;

7. People who have undergone facial surgery or deep exfoliation and have not yet reached the recovery period;

8. People who have received radioactive therapy for less than 3 months;

9. People with skin cancer at the physiotherapy site;

10. People with skin disease or inflammation, and people suffering from purulent acne;

11. It is prohibited to use in the early stage after surgery or in trauma areas;

After-sales instructions

  1. From the date the instrument leaves the factory (subject to the factory barcode of the machine), Party A will provide Party B with one-year free maintenance and lifetime maintenance after-sales service for the main unit (excluding the handle).
  2. From the date the instrument leaves the factory (based on the machine's factory barcode), the handles of all models are guaranteed for free for three months, except for human factors. (Human factors refer to unconventional instrument operations, such as not adding water, breaking it, etc.)
  3. Laser aiming heads and E-light inserts are not covered by the warranty. Consumables such as treatment heads that have a fixed number of points are covered by our warranty for half of the points.
  4. Within 7 days after the instrument leaves the factory (15 days abroad), if the machine has quality problems (non-human and force majeure), our company will provide free replacement service. If the customer sends the goods back according to the freight specified by our company, our company will bear the two-way freight.
  5. From 15 days to one year after the instrument leaves the factory, if the machine has quality problems (non-human and force majeure), our company will provide free maintenance services and free parts replacement services. If the whole machine is not returned to the factory for repair, you can do it yourself under the guidance of our engineers Remove the accessories and return them to the factory. After the accessories are repaired, we will guide the installation. If it is necessary to provide accessories first due to factors such as long distances, time constraints, etc., we will charge the accessories fee first, and return the damaged accessories to the factory for a full refund within one month. If the accessories cannot be returned in time, they will be deemed to have been shipped (within three months for foreign customers) ). The original packaging must be retained when the complete machine is returned to the factory. We are not responsible for any damage caused by packaging problems during the journey. The customer and our company are each responsible for the one-way shipping costs for accessories or complete machines. If engineers need on-site service, the customer will provide round-trip travel expenses (except Guangzhou);
  6. If there is a quality problem with the machine more than one year after the instrument leaves the factory, Party A will provide Party B with a paid warranty and only charge the cost of replacement parts (the warranty period for replacement parts is 3 months) and the travel expenses of the engineer. If you need to return to the factory for repair, two-way shipping and parts replacement fees will be charged.

Note: All products produced by our company are precision instruments and cannot be transported frequently. We can provide warranty for instrument quality problems caused by transportation, but we are not responsible. The original packaging is very important for future upgrades and repairs of the instrument, and we recommend that customers keep it. The factory barcode is the only proof of warranty. Tear off the barcode and you will not be entitled to warranty service. The company reserves the right of final interpretation and modification of the after-sales instructions.